Voltage/Amperage: See Matrix above Maximum Load with External Rectifier and Battery Inputs: 40 amps Regulation: Line: ± 1 %, Load: ± 2 % Ripple:± 1 %External Rectifier Input: 24V, 48V only; 560 or 1,000 watt (see PM Series) External Battery Bank:12V/24V/48VChassis: Aluminum Rack Size: 19″ or 23″, 2 RU (3.5″) Cooling: Forced Air Dimensions: 3.5″H x 17″W x 18″D Weight:33 Lbs. (with batteries), 17 Lbs. (without batteries)Type: 12 Volt, 5 A-H Sealed Lead-Acid, Maintenance-Free Amp-Hour Capacity: See Matrix below Weight: 4 Lbs. each; 4 Batteries per Unit Approvals:UL Recognized, DOT and IATA, approved for shipment by airSystem “Nominal” indicator lights: 1. AC OK 2. External Rectifier ON/OK – Except IPS-12-40 3. Internal Rectifier On/OK 4. Battery Contactor Closed System “Warning” indicator lights: 1. Check System 2. Battery Disconnected Form C Alarm Contacts: 1. Summary Failure 2. AC Input Failure (Optional).
[PDF Version]
This system is designed to provide regulated 24V power for industrial equipment, while providing battery backup power in the event of a source power interruption. The system features flexible AC or DC input, with low output ripple along with short circuit, overvoltage and overload protection.
What is included in a battery management system?
It is equipped with all hardware features to manage and maintain a battery without additional external components, including a built-in pre-charge circuit, on-board current measurement, mosfet power switches for battery disconnect, and a DC/DC power supply.
The system features flexible AC or DC input, with low output ripple along with short circuit, overvoltage and overload protection. The integrated charge controller continuously maintains the correct charge level on the battery and ensures a seamless power transition to battery power when needed for a complete UPS power supply solution.
What is a precision regulated power supply?
Models available for -48, +24 and +12 volt applications. Precision regulated power supply simultaneously maintains batteries at peak charge and supplies system load. Built-in batteries instantly power load during AC failure--no switch-over delay. 3-5 year average life.
What is a compact switching power supply?
The compact switching power supply has a built-in UPS charge controller, and optional DIN mount 24V 1.2AH battery pack. This system is designed to provide regulated 24V power for industrial equipment, while providing battery backup power in the event of a source power interruption.
What is included in a pre-wired power supply/Charger?
A precision regulated power supply/charger, back-up battery, low voltage battery disconnect, output metering, LED status and Form C alarm contacts are all pre-wired and calibrated within the unit for plug-and-play operation.